Find out more6 September 2017
We have recently been approached by a number of builders in respect of compliance of boiling water taps which provide boiling water via a tap connected to a small tank under the kitchen worktop.
There are three basic variants to these taps:
Taps of the type described in a) or b) above are not compliant with statutory requirement G3 (3) (a) of the Building Regulations. Requirement G3 (3) (a) limits the temperature at which hot water can be stored in a vessel to a maximum of 100 degrees centigrade. These systems provide boiling water to the tap from a tank where the water is stored at a temperature in excess of 100 degrees centigrade, hence contravening the requirement.
Where these taps are found to be installed on site, we will be unable to issue CML or Building Control Final Certificates until the issue is resolved. The only current options for this to be resolved would be:
Note that as an Approved Inspector, we do not have the power of relaxation/dispensation, so for NHBC Building Control sites, such applications must still be made to the relevant local authority.
Boiling water taps of the type described in paragraph c) above do not contravene regulation G3 (3 )(a) and continue to be acceptable.
Stay ahead of the competition with the latest technical news and updates.
Find out moreTo help you interpret and apply the NHBC Standards we produce Technical Guidance Documents on the page below.
Find out moreNHBC is uniquely placed to offer relevant, best practice technical training.
View coursesYour essential guide to house building from foundations to roofs and finishing.
Read moreTechnical queries and quotes